Each file summarizes the results of different masonry type. Note, that all the compression properties are evaluated considering the cross-section of the cap.

	Data in each column are as follows: (in parentheses the unit is shown):
	   Sample ID, Diameter(mm), Area of capping mortar(mm2), Area of core(mm2), Compressive strength(MPa), Young's modulus(MPa), Lateral stiffness (MPa),  Fracture energy (N/mm), Poisson ratio (-), Strain at peak ().  


	In the first part, the results of core specimens with 100 mm in diameter are listed.
	In the second part, the results of core specimens with 150 mm in diameter are listed.
	In the third part, the results of wallets are listed.