%% Figure 2c
dVe_c_left: Change in detuning voltage V_epsilon for the left panel in mV.
dVU_c_left: Change in energy voltage V_U for the left panel in mV.
S21n_c_left: Normalised charge sensor response for the left panel in arbitrary units. Normalization is equal to S21n = 10*S21 + 3.5

dVe_c_right_top: Change in detuning voltage V_epsilon for the top right panel in mV.
dVU_c_right_top: Change in energy voltage V_U for the top right panel in mV.
S21n_c_right_top: Normalised charge sensor response for the top right panel in arbitrary units. Normalization is equal to S21n = 12.5*S21 + 5

dVe_c_right_bot: Change in detuning voltage V_epsilon for the bottom right panel in mV.
dVU_c_right_bot: Change in energy voltage V_U for the bottom right panel in mV.
S21n_c_right_bot: Normalised charge sensor response for the bottom right panel in arbitrary units. Normalization is equal to S21n = 20*S21 + 17.2

%% Figure 2d
dVe_d_left: Change in detuning voltage V_epsilon for the left panel in mV.
dVU_d_left: Change in energy voltage V_U for the left panel in mV.
S21n_d_left: Normalised charge sensor response for the left panel in arbitrary units. Normalization is equal to S21n = 10*S21 + 3.5

dVe_d_right_top: Change in detuning voltage V_epsilon for the top right panel in mV.
dVU_d_right_top: Change in energy voltage V_U for the top right panel in mV.
S21n_d_right_top: Normalised charge sensor response for the top right panel in arbitrary units. Normalization is equal to S21n = 12.5*S21 + 5.375

dVe_d_right_bot: Change in detuning voltage V_epsilon for the bottom right panel in mV.
dVU_d_right_bot: Change in energy voltage V_U for the bottom right panel in mV.
S21n_d_right_bot: Normalised charge sensor response for the bottom right panel in arbitrary units. Normalization is equal to S21n = 25*S21 + 20.75

%% Figure 2f
tau: Readout time tau, in us
S21_ud: Charge sensor response througout the readout phase, using an |up,down> state initialization, in arbitrary units.
S21_uu: Charge sensor response througout the readout phase, using an |up,up> state initialization, in arbitrary units.

%% Figure 2g
tau_map: Readout time tau for the top panel, in us.
trace_map: Integer indicating the trace number, without units.
S21_map: Charge sensor response throughout the readoutphase, for 100 different single-shot traces.
tau_singletrace: Readout time tau for the bottom panel, in us.
S21_singletrace_block: Single charge sensor response for a spin-blockaded event, using a post-integration time of 3 us, in arbitrary units.
S21_singletrace_noblock: Single charge sensor response for a non-blockaded event, using a post-integration time of 3 us, in arbitrary units.

%% Figure 2h
shots_ud: Single-shot charge sensor response for 5000 individual shots using an |up,down> state initialization, in arbitrary units.
shots_uu: Single-shot charge sensor response for 5000 individual shots using an |up,up> state initialization, in arbitrary units.
Histograms are obtained by plotting the spread in 50 equally-sized bins in the range S21 = [-0.5,-0.9].