***This describes the content of the Concentration Data Folder***
The concentrations obtained from the field water samples across depths are presented in 
the paper, and not those from the instruments. The reading capacity of the instruments were
often exceeded and the field samples confirmed this.


*Folders
1. Field_Sample_Validation: 
- Concentration calculations from water samples at depths 20 cm, 50 cm 
and 100 cm. File are in .xlsx format. 

2. ProcessedOBS_Concentration_Data
- (Deployment 1 (D1), Deployment 2 (D2),Deployment 3 (D3),Deployment 4 (D4),
Deployment 5 (D5)); Instrument locations are aligned with the descriptions
in the data paper.Files are in .mat format. 

3. Main_Calibration_files
- The suspended sediment concentration (SSC) can be calculated with the Volts, an analog 
output from the Acoutic Doppler Velocimeters (ADVs). This is a two-step process whereby the ADV and Optical Backscatter Sensors (OBS) are connected 
and setup to the frame in the laboratory. With this, the counts are recorded for each 
addition of sediment added to the calibration vessel and this is converted to NTU values. 
- The second part of the process entails the determination of the concentration (g/l) using 
the filtration procedure. 

Files:
- Cleaning_conc.m
- coefficients_fit.mat
- Filtration_9012_conc.mat
- Plot_calibration.m
- Sed_Input.mat

Supporting Scripts
- getequationString.m
- showEquations.m